éÅÍ 1ÀÇ ÀϺκÐÀ» ¹ßÃéÇß½À´Ï´Ù.. ^^
CHAPTER1
1.1
a) True
b) True
c) True
d) False
e) True
1.2
Controlled variable- T (house interior temperature)
Manipulated variable- Q (heat from the furnace)
Solution Manual for Process Dynamics and Control, 2nd edition,
Copyright © 2004 by Dale E. Seborg, Thomas F. Edgar and Duncan A. Mellichamp.
TC
ON/OFF SWITCH
Q T L Q
1-2
Disturbance variable- QL (heat lost to surroundings); other possible
sources of disturbances are the loss of gas pressure and the outside door
opening.
Specific disturbances include change in outside temperature, change in
outside wind velocity (external heat transfer coefficient), the opening of
doors or windows into the house, the number of people inside (each one
generating and transmitting energy into the surrounding air), and what
other electric lights and appliances of any nature are being used.
1.3
The ordinary kitchen oven (either electric or gas), the water heater, and the
furnace (Ex. 1.2) all work similarly, generally using a